| Tank Type |
Cryogenic Transport Tank
|
Configuration |
Horizontal
|
Service Intended
|
LIN/LOX/Optimized for LAr
|
Gross Volume |
9345
|
Net Capacity
|
8850
|
GENERAL |
|
Overall Height |
5090 Length
|
Overall Diameter (OUT SIDE)
|
2012
|
INNER VESSEL
|
|
Material of Construction
|
SS304 |
Design & Manf. Code
|
ASME Section VII, Divn. I
|
MAWP Kg/Cm2
|
17.5 |
Safety Value Set @
|
249
|
Design Pressure
|
290 |
Hydrotest Pressure
|
377
|
Design Temperature
|
( - ) 196 To ( + ) 37°C
|
Cleaning Duty
|
Oxygen |
INSULATION SYSTEM
|
|
Type of Insulation
|
Super Insulation |
OUTER VESSEL
|
|
Material of Construction
|
CS/IS2062GrB or Equivalent
|
Desing & Manf. Code
|
CGA (-) 341 |
MAWP (EXTERNAL) Kg/Cm2
|
1.05
|
Safety Device size
|
40 KF ( X ) 3 |
Safety Device Rating Kg/Cm 2G
|
0.5
|
Safety Device Location
|
On outer shell
|
Design Pressure Kg/Cm2
|
1.05 |
Hydrotest Pressure
|
N.A.
|
THERMAL PERFORMANCE
|
|
NER Guarantee (FOR LIN) in % of capacity
|
0.60
|
PRESSURE BUILDING COIL
|
|
Tube and Flange Material
|
SS 304 |
Fin Material
|
Aluminium
|
VEHICLE TRANSPORT TANK IS OPTIMIZED FOR
|
25 Tonner (-) 2516 |
MOUNTING DETAILS OF TANK
|
As approved by CCOE
|